August 2003

 

Overnight Clinical Performance of a High Dk Overnight Clinical Performance of a High Dk Silicone Hydrogel Soft Contact Lens Silicone Hydrogel Soft Contact Lens

T.L. Comstock, O.D., M.S., M.W. Robboy, O.D., I.G. Cox, Ph.D. N.A. Brennan, Ph.D. T.L. Comstock, O.D., M.S., M.W. Robboy, O.D., I.G. Cox, Ph.D. N.A. Brennan, Ph.D.
Bausch & Lomb, Rochester, NY MOST enterprises Pty Ltd., Melbourne, Australia Bausch & Lomb, Rochester, NY, USA MOST enterprises Pty Ltd., Melbourne, Australia

 

Introduction:

Success with extended wear contact lenses has been hampered by various limitations associated with conventional hydrogels. Hypoxia has long been known as a contributing factor in many adverse corneal responses to contact lens wear, particularly extended contact lens wear. Efforts to increase the oxygen available to the cornea (Dk/t) via increased water content (Dk) and decreased thickness (t) have been insufficient to sustain successful extended wear by the majority of corneas. New efforts to raise oxygen transmissibility by incorporating highly oxygen permeable silicone into the soft contact lens matrix have dramatically increased Dk/t. The purpose of this study was to compare the corneal swelling association with overnight wear of a silicone hydrogel lens to that associate with a conventional extended wear hydrogel.

Method:
Thirty daily wear adapted soft contact lens patients were enrolled. These patients were divided into groups of ten patients each wearing -9.00 D, -3.00 D, and +4.00 D test balafilcon A (Dk99) and control etafilcon A (Dk28) lenses on contralateral eyes. On the eve of the test session baseline corneal thickness was measured using optical pachometry following 24 h of no lens wear. Lenses were then inserted and evaluated for fit and comfort. Following approximately 8 h of closed-eye overnight wear all testing was repeated.
Results:
Test eye overnight corneal swelling (4.05±2.96?) was lower and less variable than control eye swelling (9.14±4.22%), P<0.001. Mean lens movement was greater for test than for control lenses at insertion and following overnight wear.
Discussion:

Overnight corneal swelling is a direct measure of the effect of oxygen deprivation on an individual cornea. These results show that in addition to better lens movement the balafilicon A lens resulted in overnight corneal swelling levels that were significantly reduced relative to conventional extended wear hydrogel lenses and were similar to levels reported for non-lens wearers.

Download PDF of Poster: